S(F)Z11-6300~80000/110 Three-phase double-winding on-load tap-changing power transformer
The main standards implemented are GB1094, GB/16451, JB/13837, and GB24190.
Quality Assurance
Well made
Worry-free after-sales service
Quality Assurance
Classification:
66kV-220kV Oil-immersed Transformer
Tel:0371-63719330
Product Introduction
Operating Environment Conditions
1. Altitude ≤2500m
2. Max. ambient temperature; +40℃
3. Max. annual average temperature; +20℃
4. Max. daily average temperature: +30℃
5. Min. outdoor temperature: -30℃
Main Applicable Standards
GB1094、GB/16451、JB/13837、GB24190
Transformer Insulation Level
L|480AC200-L|325AC140/L|175AC35
(LV 10kV Class)
L|480AC200-L|325AC140/L|65AC25
(LV 6kV Class)
Main Technical Parameters
|
Type |
Voltage combination |
Connection |
No-Load loss |
Load loss |
No-load |
Short-circuit |
|
|
H-V |
L-V |
||||||
|
S(F)Z11-6300/110 |
110±8×1.25 |
6.3 |
YNd11 |
8.00 |
34.20 |
0.72 |
10.5 |
|
S(F)Z11-8000/110 |
9.60 |
42.75 |
0.72 |
||||
|
S(F)Z11-10000/110 |
11.36 |
50.35 |
0.67 |
||||
|
S(F)Z11-12500/110 |
13.44 |
59.85 |
0.67 |
||||
|
S(F)Z11-16000/110 |
16.16 |
73.15 |
0.62 |
||||
|
S(F)Z11-20000/110 |
19.20 |
88.35 |
0.62 |
||||
|
S(F)Z11-25000/110 |
22.72 |
104.50 |
0.58 |
||||
|
S(F)Z11-31500/110 |
27.04 |
126.35 |
0.58 |
||||
|
S(F)Z11-40000/110 |
32.32 |
148.20 |
0.52 |
||||
|
S(F)Z11-50000/110 |
38.24 |
184.30 |
0.52 |
||||
|
S(F)Z11-63000/110 |
45.44 |
222.30 |
0.47 |
||||
|
S(F)Z11-80000/110 |
52.00 |
281.00 |
0.30 |
12.0 |
|||
Note: Table 1 shows the national standard performance parameters. According to customer requirements, our company can provide products with different performance parameters.
According to customer requirements, our company can provide self-cooled products as well as products with other voltage combinations.




|
Type |
TotAL |
(mm)Out-Line Dimentaion |
|||||
|
L |
B |
H |
HL |
A1 |
A2 |
||
|
S(F)Z11-6300/110 |
25460 |
5100 |
4080 |
4800 |
6500 |
2040 |
1435 |
|
S(F)Z11-8000/110 |
28310 |
5190 |
4130 |
4860 |
6880 |
2040 |
1475 |
|
0000/11C |
31550 |
5200 |
4320 |
4870 |
7000 |
2040 |
1475 |
|
S(F)Z11-12500/110 |
35340 |
5575 |
4380 |
4910 |
7300 |
2040 |
1475 |
|
S(F)Z11-16000/110 |
39670 |
5255 |
4360 |
5175 |
7160 |
2040 |
1435 |
|
S(F)Z11-20000/110 |
43970 |
5285 |
4360 |
5310 |
7160 |
2040 |
1435 |
|
S(F)Z11-25000/110 |
46290 |
5410 |
4500 |
5330 |
8080 |
2040 |
1475 |
|
S(F)Z11-31500/110 |
55060 |
5865 |
4420 |
5500 |
8115 |
2040 |
1475 |
|
S(F)Z11-40000/110 |
62935 |
7140 |
4890 |
6195 |
8600 |
2040 |
1475 |
|
S(F)Z11-50000/110 |
78140 |
7345 |
4310 |
5330 |
8000 |
2040 |
1475 |
|
S(F)Z11-63000/110 |
81760 |
7215 |
5425 |
6700 |
8680 |
2040 |
1475 |
|
S(F)Z11-80000/110 |
90500 |
7320 |
5405 |
6870 |
9200 |
2040 |
1475 |
Note: The total weight and overall dimensions of the transformer are for reference only, and the actual dimensions shall prevail as per the outline drawing of the transformer.