Combined transformer (American-style box-type substation)
+
  • Combined transformer (American-style box-type substation)

Combined transformer (American-style box-type substation)

The ZGS series of combined transformers, also known as American-style transformers, are a series of products developed to meet the needs of urban and rural power grid construction, development, and renovation. They are transformers that combine the transformer body, switchgear, fuses, tap changers, low-voltage distribution equipment, and other corresponding auxiliary equipment to meet various configuration requirements such as power metering, reactive power compensation, and low-voltage branching.

Quality Assurance

Well made

Worry-free after-sales service

Quality Assurance

Classification:

Prefabricated substation

Product Introduction

[xss_clean][xss_clean]

ZGS series combined transformer, namely the American-style transformer, is a series of products developed according to the needs of the construction, development and renovation of urban and rural power grids. It is a transformer that combines the transformer body, switchgear, fuses, tap changer, low-voltage distribution devices and other auxiliary equipment, and can meet various configuration requirements of users such as electric energy metering, reactive power compensation and low-voltage branching.

As an independent complete power transformation and distribution device with AC 50/60HZ, 6~11kV and rated capacity of 80~1600kVA for outdoor use in power grids, the ZGS type combined transformer is widely applicable to industrial parks, urban residential quarters, commercial centers, high-rise buildings, temporary construction sites and other places.

Product Features

1. Small volume, compact structure, small floor space occupation and convenient installation

2. Low loss, low noise, low temperature rise, strong overload capacity and strong resistance to sudden short circuit.

3. Fully enclosed and fully insulated structure, safe and reliable operation.

4. Flexible connection modes: it can be used in both terminal systems and loop systems, with convenient conversion, improving the reliability of power supply.

5. Convenient operation and maintenance, short production cycle and low project cost.

Primary Wiring Diagram of the Combined Transformer (Terminal Type)

Typical Power Distribution Schemes of the Combined Transformer

Sequence
Number

Transformer capacity

Switch selection

Main configuration

 

1

 

50~500kVA

Main switch 100~1000A
Outgoing switch 100A~630A four to six circuits

Main switch:100~1000A
Outgoing switch:100A~ 630A Four to six circuits

General metering,main switch,voltmeter Three phase ammeter,reactive power
compensation 32~150kvar

 

2

 

630~800kVA

Main switch 100~1250A  Outgoing switch 100A~800A
four to six circuits

Main switch:100~1250A
Outgoing switch:100A~ 800A Four to six circuits

General metering,main switch,voltmeter Three phase ammeler,reaclive power
compensation 120~240kvar

 

3

 

1000~1600kVA

Main switch 100~2500A
Outgoing switch 100A~1000A four to six circuits

 

Main switch:100~2500A
Outgoing switch:100A~ 1000A Four to six circuits

General metering,main switch,voltmeter Three phase ammeter,reactive power
compensation 200~480kvar