SGB10/11 Unencapsulated Dry-Type Transformer
SGB non-encapsulated H-class three-phase dry-type power transformers have advantages such as safety, reliability, energy saving, strong flame retardancy, no generation of harmful gases, no environmental pollution, and simple maintenance. Their advanced design, reasonable structure, and beautiful appearance mean that their main performance indicators surpass domestic standards. They maintain excellent electrical and mechanical performance throughout their service life and are best suited for environments with high fire protection requirements, large load fluctuations, and high pollution levels, such as high-rise buildings, airports, railway stations, docks, subways, hospitals, power plants, metallurgical industries, shopping centers, densely populated residential areas, and petrochemical plants, power plants, and other similar locations.
Quality Assurance
Well made
Worry-free after-sales service
Quality Assurance
Classification:
6kV-35kV dry-type transformer
Tel:0371-63719330
Product Introduction
SGB non-encapsulated class H three-phase dry-type power transformer has the advantages of safety, reliability, energy saving, strong flame retardancy, no harmful gas generation, no environmental pollution and simple maintenance. It features advanced design and rational structure with beautiful appearance, and its main performance indexes are better than the domestic standards. It maintains good electrical and mechanical performance throughout its entire service life, and is most suitable for environments with high fire protection requirements, large load fluctuations and pollution, such as high-rise buildings, airports, stations, wharves, subways, hospitals, power plants, metallurgical industry, shopping centers, densely populated residential areas, as well as petrochemical and power station places.
Structural Features
1. Unique ceramic insulation structure: insulation cylinders and high-frequency ceramic pads are adopted, which will not deform.
2. The high and low-voltage coils are first made of NOMEX insulation material, and after multiple impregnations with specially formulated class H insulation in a VIP vacuum pressure equipment and multiple baking, the outside is sealed with high-strength insulation material and cured at high temperature. The high-voltage coil adopts a continuous structure with high mechanical strength and good heat dissipation conditions.
3. The iron core is laminated with high-permeability silicon steel sheets in a step-lap 45° fully mitered structure, and elastic fixing devices are used between the windings and the core, giving the transformer lower no-load loss and noise. The core surface is treated with a special process. The core is moderately clamped by tie rods; the upper and lower clamps are connected by tie plates and fixed together with the base and the windings as a whole; the windings are fixed by elastic pads, and the buffer structure can reduce the vibration intensity of the windings and lower the noise.
4. The lead-out terminals are fixed on the upper part of the windings, the tapping connections are located in the middle of the windings, and the low-voltage terminals are plate-type conductive bars connected by cold pressure welding.
Product Features
1. Good heat dissipation, long thermal life and strong overload capacity: under 120% long-term overload and IP45 conditions, it can operate at full load for a long time without forced air cooling. 2. Safety and flame-retardant performance: no smoke is produced under long-time combustion at 800℃.
3. Thermal shock resistance (full load can be applied immediately at -50℃)
4. The unique coil structure and field strength calculation make the partial discharge of the product small.
5. Low loss and good energy saving effect: compared with SC9 series dry-type transformers, the no-load loss is reduced by 10% on average and the load loss is reduced by 5%.
6. After the service life, the insulation material and copper wires can be easily separated and recycled, without polluting the environment.
Technical Parameter Table of SGB10 Non-encapsulated Dry-type Transformer
|
Type |
H-V |
(kV) |
L-V |
Connection |
Short |
No-Load |
Load |
No-load |
|
|
SGB10-30 |
11 |
+5% |
0.38 |
YynO |
4% |
0.19 |
0.76 |
2.0 |
|
|
SGB10-50 |
0.27 |
1.07 |
2.0 |
||||||
|
SGB1080 |
0.37 |
1.48 |
1.5 |
||||||
|
SGB10-100 |
0.40 |
1.69 |
1.5 |
||||||
|
SGB10-125 |
0.47 |
1.98 |
1.3 |
||||||
|
SGB10-160 |
0.54 |
2.28 |
1.3 |
||||||
|
SGB10-200 |
0.62 |
2.71 |
1.1 |
||||||
|
SGB10-250 |
0.72 |
2.96 |
1.1 |
||||||
|
SGB10-315 |
0.88 |
3.73 |
1.0 |
||||||
|
SGB10-400 |
0.98 |
4.28 |
1.0 |
||||||
|
SGB10-500 |
1.16 |
5.23 |
1.0 |
||||||
|
SGB10-630 |
6% |
1.30 |
6.40 |
0.9 |
|||||
|
SGB10-800 |
1.52 |
7.46 |
0.85 |
||||||
|
SGB10-100C |
1.77 |
8.76 |
0.85 |
||||||
|
SGB10-1250 |
2.09 |
10.37 |
0.85 |
||||||
|
SGB10-1600 |
2.45 |
12.58 |
0.85 |
||||||
|
SGB10-2000 |
3.05 |
15.56 |
0.7 |
||||||
|
SGB10-2500 |
3.60 |
18.45 |
0.7 |
||||||
Tag:
Related products
Related products